Compliant mechanisms for an active cardiac stabilizer: lessons and new requirements in the design of a novel surgical tool

L. Rubbert, P. Renaud, W. Bachta, and J. Gangloff

Related subject area

Mechanisms and Robotics
Fault identification of the vehicle suspension system based on binocular vision and kinematic decoupling
Hong Wei, Fulong Liu, Guoxing Li, Xingchen Yun, Muhammad Yousaf Iqbal, and Fengshou Gu
Mech. Sci., 15, 445–460, https://doi.org/10.5194/ms-15-445-2024,https://doi.org/10.5194/ms-15-445-2024, 2024
Short summary
Design and motion analysis of a new wheeled rolling robot
Hui Bian, Zihan Li, and Chang-Qian Meng
Mech. Sci., 15, 431–444, https://doi.org/10.5194/ms-15-431-2024,https://doi.org/10.5194/ms-15-431-2024, 2024
Short summary
Design and performance analysis of the 4UPS-RRR parallel ankle rehabilitation mechanism
Kan Shi, Zongjia Wang, Changtao Yan, and Zhiwei Wang
Mech. Sci., 15, 417–430, https://doi.org/10.5194/ms-15-417-2024,https://doi.org/10.5194/ms-15-417-2024, 2024
Short summary
Meshing stiffness characteristics of modified variable hyperbolic circular-arc-tooth-trace cylindrical gears
Dengqiu Ma, Bing Jiang, Zhenhuan Ye, and Yongping Liu
Mech. Sci., 15, 395–405, https://doi.org/10.5194/ms-15-395-2024,https://doi.org/10.5194/ms-15-395-2024, 2024
Short summary
Gravity compensation and output data decoupling of a novel six-dimensional force sensor
Yongli Wang, Ke Jin, Xiao Li, Feifan Cao, and Xuan Yu
Mech. Sci., 15, 367–383, https://doi.org/10.5194/ms-15-367-2024,https://doi.org/10.5194/ms-15-367-2024, 2024
Short summary

Cited articles

Awtar, S., Trutna, T., Nielsen, J., Abani, R., and Geiger, J.: FlexDex: A Minimally Invasive Surgical Tool with Enhanced Dexterity and Intuitive Actuation, ASME Journal of Medical Devices, 4, 8 pp., 2010.
Bachta, W., Renaud, P., Laroche, E., Forgione, A., and Gangloff, J.: Design and control of a new active cardiac stabilizer, IEEE/RSJ Int. Conf. on Intelligent Robotos and Systems – IROS, 404–409, 2007.
Bachta, W., Renaud, P., Laroche, E., Forgione, A., and Gangloff, J.: Cardiolock: an active cardiac stabilizer, first in vivo experiments using a new robotized device, Comput. Aided Surg., 13, 243–254, 2008.
Bachta, W., Renaud, P., Laroche, E., and Gangloff, J.: Cardiolock2: Parallel singularities for the design of an active heart stabilizer, in: ICRA, 3839–3844, 2009.
Blum, C.: Ant colony optimization: Introduction and recent trends, Phys. Life Rev., 2, 353–373, 2005.