Articles | Volume 6, issue 2
https://doi.org/10.5194/ms-6-173-2015
https://doi.org/10.5194/ms-6-173-2015
Research article
 | 
09 Sep 2015
Research article |  | 09 Sep 2015

Biomechanical comparison using finite element analysis of different screw configurations in the fixation of femoral neck fractures

K. Gok and S. Inal

Related authors

Comparison of parallel or convergent proximal schanz screw placement of pertrochanteric fixator in intertrochanteric fracture model
Arif Gok, Sermet Inal, Ferruh Taspinar, Eyyup Gulbandilar, and Kadir Gok
Mech. Sci., 8, 259–266, https://doi.org/10.5194/ms-8-259-2017,https://doi.org/10.5194/ms-8-259-2017, 2017
Short summary
Three-dimensional finite element model of the drilling process used for fixation of Salter–Harris type-3 fractures by using a K-wire
A. Gok, K. Gok, and M. B. Bilgin
Mech. Sci., 6, 147–154, https://doi.org/10.5194/ms-6-147-2015,https://doi.org/10.5194/ms-6-147-2015, 2015
Short summary

Related subject area

Subject: Biomechanics | Techniques and Approaches: Numerical Modeling and Analysis
A new methodology to identify minimum strain anatomical lines based on 3-D digital image correlation
Jorge Barrios-Muriel, Francisco Javier Alonso Sánchez, David Rodríguez Salgado, and Francisco Romero-Sánchez
Mech. Sci., 8, 337–347, https://doi.org/10.5194/ms-8-337-2017,https://doi.org/10.5194/ms-8-337-2017, 2017
Short summary
Design and evaluation of a new exoskeleton for gait rehabilitation
Ionut Daniel Geonea and Daniela Tarnita
Mech. Sci., 8, 307–321, https://doi.org/10.5194/ms-8-307-2017,https://doi.org/10.5194/ms-8-307-2017, 2017
Short summary
Comparison of parallel or convergent proximal schanz screw placement of pertrochanteric fixator in intertrochanteric fracture model
Arif Gok, Sermet Inal, Ferruh Taspinar, Eyyup Gulbandilar, and Kadir Gok
Mech. Sci., 8, 259–266, https://doi.org/10.5194/ms-8-259-2017,https://doi.org/10.5194/ms-8-259-2017, 2017
Short summary
Three-dimensional finite element model of the drilling process used for fixation of Salter–Harris type-3 fractures by using a K-wire
A. Gok, K. Gok, and M. B. Bilgin
Mech. Sci., 6, 147–154, https://doi.org/10.5194/ms-6-147-2015,https://doi.org/10.5194/ms-6-147-2015, 2015
Short summary

Cited articles

Audekercke, R. V., Martens, M., Mulier, J. C., and Stuyck, J.: Experimental Study on Internal Fixation of Femoral Neck Fractures, Clin. Orthop. Relat. Res., 141, 203–212, 1979.
Baitner, A. C., Maurer, S. G., Hickey, D. G., Jazrawi, L. M., Kummer, F. J., Jamal, J., Goldman, S., and Koval, K. J.: Vertical Shear Fractures of the Femoral Neck A Biomechanical Study, Clin. Orthop. Relat. Res., 367, 300–305, 1999.
Basso, T., Klaksvik, J., Syversen, U., and Foss, O. A.: Biomechanical femoral neck fracture experiments – A narrative review, Injury, 43, 1633–1639, 2012.
Cody, D. D., Hou, F. J., Divine, G. W., and Fyhrie, D. P.: Femoral structure and stiffness in patients with femoral neck fracture, J. Orthop. Res., 18, 443–448, 2000.
Deneka, D. A., Simonian, P. T., Stankewich, C. J., Eckert, D., Chapman, J. R., and Tencer, A. F.: Biomechanical Comparison of Internal Fixation Techniques for the Treatment of Unstable Basicervical Femoral Neck Fractures, J. Orthop. Trauma, 11, 337–343, 1997.